SEMI C48-0699E SPECIFICATION AND GUIDELINE FOR 1,1,1-TRICHLOROETHANE

SEMI C48-0699E SPECIFICATION AND GUIDELINE FOR 1,1,1-TRICHLOROETHANE

ID:44110657

大小:37.20 KB

页数:3页

时间:2019-10-18

SEMI C48-0699E SPECIFICATION AND GUIDELINE FOR 1,1,1-TRICHLOROETHANE_第1页
SEMI C48-0699E SPECIFICATION AND GUIDELINE FOR 1,1,1-TRICHLOROETHANE_第2页
SEMI C48-0699E SPECIFICATION AND GUIDELINE FOR 1,1,1-TRICHLOROETHANE_第3页
资源描述:

《SEMI C48-0699E SPECIFICATION AND GUIDELINE FOR 1,1,1-TRICHLOROETHANE》由会员上传分享,免费在线阅读,更多相关内容在行业资料-天天文库

1、ESEMIC48-0699SPECIFICATIONANDGUIDELINEFOR1,1,1-TRICHLOROETHANE*,FURNACEGRADEThisspecificationandthisguidelineweretechnicallyapprovedbytheGlobalProcessChemicalsCommitteeandarethedirectresponsibilityoftheNorthAmericanProcessChemicalsCommittee.CurrenteditionapprovedbytheNorthAmericanRegionalStand

2、ardsCommitteeonApril23,1999.InitiallyavailableonSEMIOnLineMay1999;tobepublishedJune1999.ThisdocumentreplacesSEMIC1.26andC7.15intheirentirety.Originallypublishedin1988and1991respectively.EThisdocumentwaseditoriallymodifiedinMarch2000.ChangesweremadetothetablefollowingSection8.1.*CAUTION:Reactsv

3、iolentlywithAluminumandwhite8Grade1Proceduresmetalsandisnottobeusedforvapordegreasing.(Contains8.1Assay—Determinetheassayusingasuitablegaslessthan0.05%inhibitors.)chromatograph.Integratetheareasunderallstabalizerandimpuritypeaksandthe1,1,1-trichloroethanepeak.1PurposeApplyappropriateresponsefa

4、ctorsforthecolumnand1.1Thepurposeofthisdocumentistostandardizedetectorsystemtocorrecttheresultsfromareapercentrequirementsfor1,1,1-trichloroethane,furnacegradetoweightpercent.Theassayshallnotbelessthanusedinthesemiconductorindustryandtesting99.9%byweight(seeSEMIC1,Section3.1,procedurestosuppor

5、tthosestandards.TestmethodsGuidelinesforAssaybyWideBoreColumnGashavebeenshowntogivestatisticallyvalidresults.ThisChromatography).Theparameterscitedhavegivendocumentalsoprovidesguidelinesforgradesof1,1,1-satisfactoryresults.trichloroethane,furnacegradeforwhichaneedhasNOTE1:Calibrationstandardto

6、bedeterminedbetweenbeenidentified.Inthecaseoftheguidelines,thetestsupplieranduser.methodsmaynothavebeenstatisticallyvalidatedyet.Column:30meter×530micronI.D.fusedsilica2Scopecapillary,coatedwith5micronfilmofDB-1orequivalent(100%methylsiliconewhichhasbeen2.1Thescopeofthisdocumentisallgradesof1,

7、1,1-surfacebondedandcrosslinked).trichloroethane,furnacegradeusedinthesemiconductorindustry.ColumnTemperature:40°Cisothermalfor5minutes,thenprogrammedto200°Cat10°C/min.3LimitationsInjectorTemperature:150°C3.1None.DetectorTemperature:250

当前文档最多预览五页,下载文档查看全文

此文档下载收益归作者所有

当前文档最多预览五页,下载文档查看全文
温馨提示:
1. 部分包含数学公式或PPT动画的文件,查看预览时可能会显示错乱或异常,文件下载后无此问题,请放心下载。
2. 本文档由用户上传,版权归属用户,天天文库负责整理代发布。如果您对本文档版权有争议请及时联系客服。
3. 下载前请仔细阅读文档内容,确认文档内容符合您的需求后进行下载,若出现内容与标题不符可向本站投诉处理。
4. 下载文档时可能由于网络波动等原因无法下载或下载错误,付费完成后未能成功下载的用户请联系客服处理。