1、出现arealengtherrorwhenwriting错误 DiagnosticbufferofmoduleCPU315-2DP OrderNo./DescriptionComponentVersion 6ES7315-2AH14-0AB0Hardware2 ---FirmwareV3.0.3 BootLoaderFirmwareexpansionA25.7.5 Rack:0 Slot:2 Serialnumber:SC-B2UB70082011 Event1of500:EventID16#4541 STOPca
2、usedbypriorityclasssystem Event:Cycletimeexceeded OBnumber:TimingerrorOB(OB80) Priorityclass:26 Previousoperatingmode:RUN Requestedoperatingmode:STOP(internal) Internalerror,Incomingevent 02:09:37.079AM04/18/1994 Event2of500:EventID16#3501 Cycletimeexceeded Runt
3、imeofthelastcycle(ms):6000 Cause:OB1starteventinitiatedbyendofwarmrestart CausingOB:Cyclicprogram(OB1) Causingpriorityclass:1 RequestedOB:TimingerrorOB(OB80) Priorityclass:26 Internalerror,Incomingevent 02:09:31.079AM04/18/1994 最佳答案 Cycletim
4、eexceeded Runtimeofthelastcycle(ms):6000 Cause:OB1starteventinitiatedbyendofwarmrestart CausingOB:Cyclicprogram(OB1) 上述信息表明有循环时间超时的错误,检查OB1中程序是否有死循环的现象。 TimingerrorOB(OB80): 在诊断信息描述中调用了OB80。 OB80:时间故障。可能的原因: 这样的故障包括:循环时间超出、执行OB时应答故障、向前移动时间以致于跃过了OB的启动时间、CiR后恢复RUN方式。如
5、果,例如,当循环中断OB仍在执行前一次调用时,该OB块的启动事件发生,操作系统调用OB80。如果OB80未编程,CPU变为STOP方式。您可以使用SFC39至42封锁或延时和再使能时间故障OB。 注意:如果在同一个扫描周期中由于扫描时间超出OB80被调用两次,CPU就变为STOP方式。您可以通过在程序中适当的位置调用SFC43“RE_TRIGR”来避免这种情况。 参见: 详见《组织块使用说明》下载: http://218.93.112.166/ec/C23/dl/xxzl/%E7%BB%84%E7%BB%87%E5%9D%97%E4%
6、BD%BF%E7%94%A8%E8%AF%B4%E6%98%8E.pdf