Hydrogen peroxide biosensor based on myoglobin_colloidal gold nanoparticles immobilized on glassy carbon electrode by a Nafion film

Hydrogen peroxide biosensor based on myoglobin_colloidal gold nanoparticles immobilized on glassy carbon electrode by a Nafion film

ID:39403900

大小:437.46 KB

页数:7页

时间:2019-07-02

Hydrogen peroxide biosensor based on myoglobin_colloidal gold nanoparticles immobilized on glassy carbon electrode by a Nafion film_第1页
Hydrogen peroxide biosensor based on myoglobin_colloidal gold nanoparticles immobilized on glassy carbon electrode by a Nafion film_第2页
Hydrogen peroxide biosensor based on myoglobin_colloidal gold nanoparticles immobilized on glassy carbon electrode by a Nafion film_第3页
Hydrogen peroxide biosensor based on myoglobin_colloidal gold nanoparticles immobilized on glassy carbon electrode by a Nafion film_第4页
Hydrogen peroxide biosensor based on myoglobin_colloidal gold nanoparticles immobilized on glassy carbon electrode by a Nafion film_第5页
资源描述:

《Hydrogen peroxide biosensor based on myoglobin_colloidal gold nanoparticles immobilized on glassy carbon electrode by a Nafion film》由会员上传分享,免费在线阅读,更多相关内容在学术论文-天天文库

1、SensorsandActuatorsB115(2006)4248Hydrogenperoxidebiosensorbasedonmyoglobin/colloidalgoldnanoparticlesimmobilizedonglassycarbonelectrodebyaNafionfilmWeiweiYang,YancaiLi,YuBai,ChangqingSun∗CollegeofChemistry,JilinUniversity,Changchun130012,PRChinaReceived26

2、April2005;receivedinrevisedform31July2005;accepted3August2005Availableonline29September2005AbstractAnovelamperometricsensorofhydrogenperoxidewasdevelopedbasedontheimmobilizationofmyoglobin(Mb)andcolloidalgoldnanopar-ticles(CGNs)onaglassycarbonelectrode(

3、GCE)byaNafionfilm.TheimmobilizedMbdisplayedapairofwell-definedandnearlyreversiblecyclicvoltammetricpeakswithaformalpotential(E◦)of−0.373Vina0.1Mphosphatebuffersolution(PBS)ofpH6.9.TheformalpotentialoftheMbhemeFe(III)/Fe(II)coupleshiftedlinearlywithpHwitha

4、slopeof−49.6mV/pH,indicatingthattheelectrontransferisaccompaniedbysingle-protontransportation.TheimmobilizedMbexhibitedexcellentelectrocatalyticresponsetothereductionofhydrogenperoxide,basedonwhichanunmediatedbiosensorforhydrogenperoxidewasachieved.Thel

5、inearrangefordeterminationofhydrogenperoxidewasfrom1.5×10−6to9.0×10−5Mwithadetectionlimitof5.0×10−7Matasignal-to-noiseratioof3.Thestability,repeatabilityandselectivityofthebiosensorwerealsoevaluated.©2005ElsevierB.V.Allrightsreserved.Keywords:Myoglobin;

6、Colloidalgoldnanoparticles;Directelectrochemistry;H2O2biosensor;Nafion1.IntroductionimmobilizedHRP[1014].ButitisstillnecessarytofindothersubstitutesforHRPtofabricatenovelH2O2biosensors.Myo-Theaccuratedeterminationofhydrogenperoxide(H2O2)globin(Mb)isknownt

7、ohavesomeintrinsicperoxidaseactivityplaysanimportantroleinmanyfieldsincludingindustry,clini-duetoitsclosesimilaritytoperoxidase.Therefore,itmightbecalcontrolandenvironmentalprotection[13].ManytraditionalpossibletoemployMbcontainingahemegroupthatservesast

8、echniquessuchastitrimetry[4],spectrophotometry[5],chemi-theactivecentertocatalyzethereductionofH2O2.However,luminescence[6]havebeenemployedforthispurpose.How-electrontransferbetweenMbandbaresolidelectrodesisusu-ever,manyofthesepr

当前文档最多预览五页,下载文档查看全文

此文档下载收益归作者所有

当前文档最多预览五页,下载文档查看全文
温馨提示:
1. 部分包含数学公式或PPT动画的文件,查看预览时可能会显示错乱或异常,文件下载后无此问题,请放心下载。
2. 本文档由用户上传,版权归属用户,天天文库负责整理代发布。如果您对本文档版权有争议请及时联系客服。
3. 下载前请仔细阅读文档内容,确认文档内容符合您的需求后进行下载,若出现内容与标题不符可向本站投诉处理。
4. 下载文档时可能由于网络波动等原因无法下载或下载错误,付费完成后未能成功下载的用户请联系客服处理。