1、METHOD9079SCREENINGTESTMETHODFORPOLYCHLORINATEDBIPHENYLSINTRANSFORMEROIL1.0SCOPEANDAPPLICATION1.1Method9079maybeusedtoscreenhydrocarbonbasedelectricalinsulatingfluidsforpolychlorinatedbiphenyls(PCBs)atpresetlevelsof20,50,100,or500µg/g.Themethodisdesignedtoprovidescree
2、ningdataoutsideofalaboratoryenvironmentinunder10minutes,providingacolorimetricindicationthattheconcentrationofPCBsisaboveorbelowthefixedendpoint.Screeningproceduresmaysignificantlyreducethenumberofsamplesrequiringlaboratorytesting.1.2ChlorinesareremovedfromthePCBmolec
3、uleusinganorgano-sodiumreagent.Theresultingchlorideionsaremeasuredusingacolorimetricindicator.1.3Thismethodisrestrictedtousebyorunderthesupervisionoftrainedanalysts.Eachanalystmustdemonstratetheabilitytogenerateacceptableresultswiththismethod.2.0SUMMARYOFMETHOD2.1Asam
4、pleoftheoiltobetestedisreactedwithamixtureofmetallicsodiumcatalyzedwithnaphthaleneanddiglymeatambienttemperature.Thisprocessconvertsallorganichalogenstotheirrespectivesodiumhalides.Allhalidesinthetreatedmixture,includingthosepresentpriortothereaction,arethenextractedi
5、ntoanaqueousbuffer,apremeasuredamountofmercuricnitrateisadded,followedbyasolutionofdiphenylcarbazoneastheindicator.2.2Thecolorofthesolutionattheendofthetestindicateswhetherthesampleisaboveorbelowthepresetchlorinelevel.Ayellowendpointindicatesaconcentrationgreaterthant
6、hesetpointofthetestandablue-violetendpointindicatesaconcentrationlessthanthesetpointofthetest.2.3TheendpointatwhicheachofthetestkitsturnspositiveiscalibratedusingAroclor1242standards.Aroclor1242providesaconservativeendpointduetoitslowchlorinecontentrelativetotheotherA
7、roclorsusedinelectricalequipment.AlistofAroclorsusedinelectricalequipmentandthePCBconcentrationthatgivesapositiveindicationusingthe50µg/gtestkitisgiveninTable1.3.0INTERFERENCES3.1Waterpresentinthesampleatmorethan2%maycausealowreading.Waterpresentatthishighalevelresult
8、sinanobviouschangeinthesodiumreactionandtheusershouldstopthetest.3.2Highsulfurlevels(4%)willcauseahighbiaspossiblyresultingi
此文档下载收益归作者所有