《引风机节能技术 ENHANCING ENERGY EFFICIENCY OF INDUCED DRAFT FANS IN THERMAL POWER PLANTS》由会员上传分享,免费在线阅读,更多相关内容在教育资源-天天文库。
1、ProceedingsoftheEighthTASTEDInternationalConferencePOWERANDENERGYSYSTEMS(EuroPES2008)June23-25,2008Corfu,GreeceENHANCINGENERGYEFFICIENCYOFINDUCEDDRAFTFANSINTHERMALPOWERPLANTS608-069176RajashekarP.MandiCentralPowerResearchInstitute,Bangalore,Indiarajashekarmandi@yahoo.comABSTRAC
2、T:Thispaperdescribesthevariousmethodsforenhancingtheenergyefficiencyofinduceddraftfansincoalfiredthermalpowerplants.Theauxiliarypowerusedbyinduceddraftfansformsabout1.4%to1.8%ofthetotalgrossenergygeneration.IDfansarethesecondlargest(inrating)motorinathermalpowerplantafterBoiler
3、FeedPump(BFP).Thedetailedenergyauditofauxiliaryequipmentinvariousthermalpowerstations,operationaloptimizationandappropriatecontrolsystemhadshownamplescopeforimprovingtheenergyefficiencyofinduceddraftfans.Theimplementationofenergyconservationmeasuresreducetheaverageauxiliarypowe
4、rusedbyIDfansfor210MWplantfrom1.63%to0.97%ofgrossenergygenerationandtheenergyconservationschemesareeconomicallyattractivewithapaybackperiodof1to5years.KEYWORDS:Energyefficiency,Auxiliarypower,fanefficiency,SEC,VFD,excessair1.IntroductionCoalfiredstationsarethebackboneofIndianpo
5、wergeneratingsectorandaccountforover76%ofthegeneratedpower[1,2].Thenetoverallefficiencyofcoalfiredthermalpowerplantsareintherangeof19.23%(30MWplant)and30.69%(500MWplant).Theauxiliarypowerisvaryingbetween7%(500MWplant)and12%(30MWplant).Thethermalpowerplantavailabilitydependslarg
6、elyupontheoperationalreliabilityoftheauxiliaryequipmentandthecapabilityoftheauxiliarysystem[3].Theboilersusedforpowergenerationgenerallyworkontheprincipleofbalanceddraftsystemi.e.,bothForcedDraft(FD)&PrimaryAir(PA)fansforpushingairintothefurnaceandInducedDraft(ID)fanstosuckthef
7、luegasfromthefurnace&throwoutthefluegastoatmospherethroughchimney.Figure1givestheschematicoffluegascircuitinthermalpowerplant.Ineachpowerboiler,generallytherewillbetwoIDfansforplantsizeof210MW&belowsizeandfourIDfansfor500MWplants.IDfanshavetohandlelargequantityoffluegasathigher
8、temperature.Thefluegasflowwillbecontrolledeitherbyinle