桡骨远端骨折手法复位电子智能夹板固定的临床分析

桡骨远端骨折手法复位电子智能夹板固定的临床分析

ID:31853731

大小:1.38 MB

页数:44页

时间:2019-01-21

桡骨远端骨折手法复位电子智能夹板固定的临床分析_第1页
桡骨远端骨折手法复位电子智能夹板固定的临床分析_第2页
桡骨远端骨折手法复位电子智能夹板固定的临床分析_第3页
桡骨远端骨折手法复位电子智能夹板固定的临床分析_第4页
桡骨远端骨折手法复位电子智能夹板固定的临床分析_第5页
资源描述:

《桡骨远端骨折手法复位电子智能夹板固定的临床分析》由会员上传分享,免费在线阅读,更多相关内容在应用文档-天天文库

1、桡骨远端骨折手法复位电子智能夹板固定的临床研究ABSTRACTObservation:TomeasuretheeffectofTheelectronicintelligencesplintandthetraditionalsplintinpatientswithdistalradialfractures,andtocomparethedifferencesbetweenthem.Forexamplecomplications,fracturehealing,recoveryofwristfunction。Monitoringresetelectronicintellig

2、encesplinttightnessaccuracyandthetimelinessoftheeffectivepreventionofcomplications,feasibility。Thesametimeimproveandquantifythetechnicalstandardsofelectronicintelligencesplintpressure,andpromotethemodernizationofsplinttechnologyMethods:Thestudywasperformedonpatientswithdistalradialfractu

3、reswhopresentsinHospitalofgansuprovinceOrthopaedicEmergencydepartmentbetweenOctober2010toOctober2011,sixtypatientschosenbyadoptionstandardsanddiagnosedwithdistalradialfractureswererandomlydividedintotwogroups(Theelectronicintelligencesplintgroup30casesandthetraditionalsplintgroup30cases)

4、,Tostudytheeffectofthesetwotherapyon60sufferersafter6months.WeusedGartlandandWerlle’swristjointscoringstandardstoevaluatethecurativeeffect.FromtheResidualdeformity,subjectiveevaluation,objectivemeasuresandcomplicationsintermsofevaluation.followingfouraspects,Priorityof0to2,goodin3to8poin

5、tscanbe9to20,poor20points。Imagingevaluationbeforetreatmentandafter6weeksafterulnardeviation,palminclination,radialheightofthreeaspectsoftheevaluation.Andafter2weeks,swelling,painassessment。Results:Aftertreatmentforsixmonths,wefoundthatthereisasignificantdifferentbetweentheelectronicintel

6、ligencesplintgroupandthetraditionalsplintgroupinimageology,swellingscoringsystemandpainscoringsystem.WristscoreaccordingtoGartlandandWerlley。Bytherankandtestingofelectronicsplintgroupandtraditionalsplintgrouptwosetsofresults,Z=2.084,P=0.037,p<0.05。Thedifferencewasstatisticallysignificant

7、。Theimagingdatabetweenthetwogroupswerecomparedusinggroupt-test,。ByP>0.05。Thedifferencewasnotstatisticallysignificant。Accordingtotheswellingscore。electronicintelligencesplintgroupandtraditionalsplintgroupbetweenthetwogroupswerecomparedusingnon-parametricMann-WhitneyUtest,B