资源描述:
《多排螺旋ct骨盆低剂量扫描技术的应用》由会员上传分享,免费在线阅读,更多相关内容在工程资料-天天文库。
1、多排螺旋CT骨盆低剂量扫描技术的应用李耀平邱国华梁飞虎(广东省高州市中医院广东高州525200)【摘要】目的评价骨盆螺旋CT低剂量与常规剂量扫描的图像质量,探讨骨盆低剂量螺旋CT扫描时合理剂量选择及其应用价值。方法回顾性总结120例需行骨盆CT检查患者,在常规剂量(200mA)螺旋CT扫描后,其它参数不变,仅改变管电流(100mA50mA和30mA)进行螺旋CT扫描,根据不同mA值共分成4组,分析比较常规剂量与低剂量图像及辐射剂量的差异。结果①低剂量(100mA50mA和30mA)的CTDIvol值为常规剂fi:(200mA)的50%、25
2、%和15%。②图像质量评价结果100mA与50mA的可诊断图像进行t检验,P>0.05,差异无统计学意义,满足诊断要求;30mA可诊断图像t检验,P<0.01,提示图像质量差,不能满足诊断要求。结论合理选择低剂量骨盆螺旋CT扫描技术,有利于降低患者所接受的射线剂量,也能取得与常规CT扫描相同的图像质量,同时减少性腺辐射剂量,延长昂贵球管寿命,值得进一步推广应用。【关键词】多排螺旋CT低剂量图像质量骨盆【中图分类号】R445【文献标识码】A【文章编号】2095-1752(2013)18-0104-02Applicationofmu
3、lti-slicelow-dosespiralCTscanningtechnologyinthepelvisliYaoping,Qiuguohuajiangfeihu(GuangdongProvinceTCMHospitalofGaozhou,Gaozhou525200)【Abstract】Objective:Toevaluatetheimagequalityoflow-dosespiralCTscanningandconventionaldose,lowdosespiralCTscanningofthepelvisisreasonable
4、choiceofdoseanditsapplicationvalue.Methods:aretrospectivereviewof120casesofpelvicCTexaminationforpatients,intheconventionaldose(200mA)ofspiralCTscanning,theotherparametersconstant,changingonlythetubecurrent(100mA50,mAand30mA)werescannedbyspiralCT,accordingtothedifferentmAv
5、aluesweredividedinto4groups,analysisofdifferencebetweenconventionaldoseandlowdoseimageandradiationdose.Results:①lowdose(100mA50mAand30mA)ofCTDIvolvalueofroutinedose(200mA)of50%,25%and15%.Resultstheimagequalityevaluationof100mAand50mAcanbediagnosticimagesbyusingttest,P>0
6、.05,thedifferencewasnotstatisticallysignificant,meetthediagnosticrequirements;30mAdiagnosisimagettest,P<0.01,indicatingthatimagequalityispoor,cannotmeetthediagnosticrequirements.Conclusions:selectionoflowdosepelvicspiralCTscanningtechnology,helpstoreducetheradiationdose
7、receivedbythepatients,alsocanobtainthesameimagequalityandconventionalCTscanning,whilereducingthegonadalradiationdose,prolongtheexpensivebulblife,worthyoffurtherapplication.【keyword】multi-slicespiralCTlowdoseimagequalitypelvis随着多排螺旋CT的出现及苏广泛应用,在临床医疗诊断中发挥了重要作用。同吋也使医源性射线对人体的辐
8、射量变得越来越多。骨盆部奋人体对射线高度敏感的性腺组织;因此,行骨盆螺旋CT扫描吋必须采取措施给予防护。本文通过仅降低CT扫描吋mAs值,.其他参数不变来减少射线剂量,分析其对图