《射线检查程序RADIOGRAPHIC EXAMINATION PROCEDURE》由会员上传分享,免费在线阅读,更多相关内容在行业资料-天天文库。
1、RADIOGRAPHICEXAMINATIONPROCEDUREFORBUTTWELDSRevision0Date30/04/2017Page19of19RADIOGRAPHICEXAMINATIONPROCEDURE3210REVISIONPREPAREDBYREVIEWEDBYAPPROVEDBYAIRADIOGRAPHICEXAMINATIONPROCEDUREFORBUTTWELDSRevision0Date30/04/2017Page19of191.General1.1Thisprocedureisapplied
2、tothex-rayradiographicexaminationofweldsforpressurevesselsinaccordancewithASMECodeSectionI、SectionVandSectionⅧDivision1&2.1.2Thisprocedureisusedtodefectdiscontinuitiesinferrousweldsandwaterialwithathicknessrangebetween4mmand50.8mm.2.QualificationofExaminationPerso
3、nnel2.1Anypersonengagedintheradiographicexaminationshallbequalifiedandcertifiedasaradiographicexaminerinaccordancewith“WrittenPracticeforNDEPersonnelTraining,Examination,QualificationandCertification”2.2RadiographersshallbeatleastlevelⅠ,Radiographicinterpreterssha
4、llbeatleastlevelⅡ.3.Equipment,ToolsandMaterials3.1x-rayequipmentshallbeselectedfromTable1.Table1TypeManufactoryMax.TubeVoltage(kVp)Max.TubeCurrent(mA)Focus.Size(mm)Permittedmax.materialthickness(mm)(steel)300EG-S3RIGAKVCORPORATION30052.5×2.550250EG-S3RIGAKVCORPORA
5、TION25052.0×2.0303.2Film3.2.1FilmselectionshallbeinaccordancewithASTME-1815,StandardTestMethodforFilmSystemsforIndustrialRadiography.Theclassificationtableoffilmshallbeprovidedbythefilmmanufacturer.FilmsystemclassesSpecial,Ⅰ,Ⅱ,Ⅲ,W-A,andW-Barepermitted.RADIOGRAPHIC
6、EXAMINATIONPROCEDUREFORBUTTWELDSRevision0Date30/04/2017Page19of19Dependingonthex-raypenetrationthickness,asuitablefilmshallbeselected.Whenusingtwofilmsmethod;twodifferenttypesoffilmshallbeselected.3.2.2FilmKODAKAA400maybeused.3.3IntensifyingScreensAsuitableleadscr
7、eenshallbeselectedfromTable2.Table2TubeVoltageThicknessofleadScreen(mm)FrontBack<150kVp0.030.03150~300kVp0.030.103.4DensitometerandStepWedgeCalibrationFilm3.4.1ThetransmissiondensitometerlistedinTable3shallbeusedforjudgingradiographdensity.Thedensitometershallbeca
8、libratedagainstthestepwedgecalibrationfilmatleastevery90daysduringusebytheNDELevelⅡorⅢExaminer,inaccordancewith“DensitometerCalibrationProcedure”.Theste