micro-ct评价即刻负载对ss和ti微种植体周围组织的影响

micro-ct评价即刻负载对ss和ti微种植体周围组织的影响

ID:34157605

大小:2.11 MB

页数:35页

时间:2019-03-03

micro-ct评价即刻负载对ss和ti微种植体周围组织的影响_第1页
micro-ct评价即刻负载对ss和ti微种植体周围组织的影响_第2页
micro-ct评价即刻负载对ss和ti微种植体周围组织的影响_第3页
micro-ct评价即刻负载对ss和ti微种植体周围组织的影响_第4页
micro-ct评价即刻负载对ss和ti微种植体周围组织的影响_第5页
资源描述:

《micro-ct评价即刻负载对ss和ti微种植体周围组织的影响》由会员上传分享,免费在线阅读,更多相关内容在教育资源-天天文库

1、2内蒙古医科大学硕士研究生学位论文(2015)Effectofimmediateloadingontheperi-implanttissueofstainlesssteelandtitaniumalloymini-implants:AmicrocomputedtomographicanalysisAbstractObjective:Themainaimofthispaperisthroughtheapplicationofmicro-CT,scansformini-implants,3Dreconstructioninmini-pigsjawimplantandsur

2、roundingbonemineraldensitymeasurement,compareimmediateloadstainlesssteelmini-implantsandtitaniumalloymini-implantssuccessrateanditsimpactonthesurroundingtissue.Inordertotheclinicalapplicationofstainlesssteelmini-implantsexperimentalbasis.Methods:Twentyfourstainlesssteelmini-implantsandt

3、wentyfourtitaniumalloymini-implantswereplantedinthebuccalsidesofthejawofmini-pigsbyself-drilling.Twogroupsofmini-implantsleftandrightsidesissymmetricaldistribution,andthenumberofthefracturedmini-implantswasrecorded.Approximately200gconstantandcontinuousforcebystretchingclosednickel-tita

4、niumspringswereimmediateloadedforeverytwoadjoinedmini-implantsfortenweeks.Andnickeltitaniumtensionspringlengthmeasurement.Checkthestabilityofthemini-implants,anddentaltweezerstomeasuremini-implantsloosedegree.Aftertenweeks,themini-pigswerekilled,againtodetectmini-implantsloosedegree.The

5、numberofremainingmini-implantsinthetwogroupswasrecorded.ApplicationofSPSSsoftwareanalyzethesuccessrateofstainlesssteelandtitaniumalloymini-implants,withstatisticalsignificance(p<0.05).AccordingtoXrayfourstainlesssteelandfourtitaniumalloymini-implantsrespectivelywerechosentomakeMicro-CTs

6、canning.UsingiCAT3Dsoftwareforanalyzingthree-dimensionalimages,TC-Analyserdedicatedskeletalanalysissoftware,mini-implantsbonedensitymeasurementsaround,gettrabeculardifferentindicatorsdata,Comparewithimmediateloadingofstainlesssteelandtitaniumalloymini-implantssurroundingbonemineraldensi

7、ty.Results:①Stainlesssteelmini-implantsandtitaniumalloymini-implantshadgoodinitialstability;②Stainlesssteelmini-implantsbrokentwo,brokenratewas7.69%,titaniumalloymini-implantsbrokenfive,brokenratewas17.24%.Itcanbeseenthatthestainlesssteelmini-implantsbrokenratewaslowerthantheti

当前文档最多预览五页,下载文档查看全文

此文档下载收益归作者所有

当前文档最多预览五页,下载文档查看全文
温馨提示:
1. 部分包含数学公式或PPT动画的文件,查看预览时可能会显示错乱或异常,文件下载后无此问题,请放心下载。
2. 本文档由用户上传,版权归属用户,天天文库负责整理代发布。如果您对本文档版权有争议请及时联系客服。
3. 下载前请仔细阅读文档内容,确认文档内容符合您的需求后进行下载,若出现内容与标题不符可向本站投诉处理。
4. 下载文档时可能由于网络波动等原因无法下载或下载错误,付费完成后未能成功下载的用户请联系客服处理。