《离子膜电解槽运行总结》由会员上传分享,免费在线阅读,更多相关内容在行业资料-天天文库。
1、6万吨/年离子膜烧碱装置运行总结该装置2011年1月1日开车,由于工艺、电器、仪表的原因,造成电解槽装置系统频繁的连锁调停,通过进一步消缺,2011年1月23日,电解槽装置满负荷运行,离子膜电解槽在2011年1月—12月期间,槽电压上升幅度很大,槽电压变化情况如下:复极式离子膜2011年1-12月份槽电压统计序号月份运行电流实测电压(V)校核电压V′槽电压的变化(△Ⅴ)直流电耗Cl2纯度O2/Cl2NaOH(%)NaCl/NaOH槽号1一12.13.053.052129 32.26 A槽212.13.083.082150 32.
2、44 B槽312.13.073.072143 32.36 C槽4二12.23.113.13218599.20.330.43 A槽512.23.163.18222099.40.130.29 B槽612.23.233.25226999.60.130.44 C槽7三12.23.133.15222299.00.530.410.001278A槽812.23.153.17223699.00.530.350.001182B槽912.23.163.18224499.00.530.490.001590C槽10四12.23.103.12220198.
3、80.730.330.001173A槽1112.33.123.14221598.90.630.20.002224B槽1212.33.143.16222998.5130.140.002765C槽13五12.33.133.14221598.60.930.510.00374A槽1412.33.163.14221598.60.930.270.002152B槽1512.33.173.18224498.60.930.340.005434C槽16六12.113.133.16222998.5130.680.001913A槽1712.163.143.
4、17223698.70.830.310.003461B槽1812.23.143.16222998.70.830.330.002013C槽19七12.043.13.14221598.5130.370.003206A槽2012.173.113.14221598.60.930.360.003846B槽2112.213.123.15222298.80.730.180.003167C槽22八12.113.143.17223698.80.730.210.003433A槽2312.153.143.17223698.70.830.350.00443
5、7B槽2412.223.163.18224498.80.730.350.003556C槽25九7.892.953.30232898.41.130.630.005443A槽267.962.953.30232898.5130.630.006562B槽277.972.973.32234298.70.830.590.006184C槽1028十8.893.023.30232898.5130.240.006804A槽298.963.043.31233598.70.830.260.007638B槽308.963.053.32234298.41.1
6、30.40.008022C槽31十一8.893.063.34235698.80.730.440.006562A槽328.943.053.32234298.70.830.480.006396B槽338.973.073.34235698.70.830.480.00477C槽34十二6.92.983.41240698.70.830.70.006786A槽356.9772.963.31233598.80.730.690.006565B槽366.952.993.42241398.70.830.730.007296C槽2011年1-12月份槽电
7、压变化趋势图一、开停车频繁对离子膜电解槽装置的影响一、离子膜电解槽频繁开停车对离子膜电解槽的影响2011年1月23日11分,电解槽运行电流12.2KA,测定电解槽的性能消耗指标A电解槽B电解槽C电解槽槽电压V校核槽电压V直流电耗KW.H/T槽电压V校核槽电压V直流电耗KW.H/T槽电压V校核槽电压V直流电耗KW.H/T3.0633.08421533.0723.09321593.0893.112171电解槽的直流电耗高于考核值(在开车后的1个月之内,电解槽的直流电耗小于2120KW.H/T),具体原因是因为开停车次数频繁10,A电解槽
8、停4次,B电解槽停7次,C电解槽停14次,导致C电解槽直流电耗高达2171KW.H/T,高于考核指标51KW.H/T。在2011年,A电解槽停32次,B电解槽停34次,C电解槽停37次,离子膜电解槽要求平稳的运行,开停车对离子膜损伤很
此文档下载收益归作者所有