qgdw-435-2010《农村电网无功优化补偿技术导则》

qgdw-435-2010《农村电网无功优化补偿技术导则》

ID:9807365

大小:176.21 KB

页数:41页

时间:2018-05-10

qgdw-435-2010《农村电网无功优化补偿技术导则》_第1页
qgdw-435-2010《农村电网无功优化补偿技术导则》_第2页
qgdw-435-2010《农村电网无功优化补偿技术导则》_第3页
qgdw-435-2010《农村电网无功优化补偿技术导则》_第4页
qgdw-435-2010《农村电网无功优化补偿技术导则》_第5页
资源描述:

《qgdw-435-2010《农村电网无功优化补偿技术导则》》由会员上传分享,免费在线阅读,更多相关内容在行业资料-天天文库

1、国家电网公司文件国家电网科〔2010〕342号关于印发《农村电网无功优化补偿技术导则》等标准的通知公司各单位、总部各部门:根据《国家电网公司技术标准管理办法》规定,《农村电网无功优化补偿技术导则》、《配电线路故障指示器技术规范》已经通过审查,现批准为国家电网公司技术标准并予以印发,自印发之日起实施。—1—附件:1.Q/GDW435-2010《农村电网无功优化补偿技术导则》及编制说明2.Q/GDW436-2010《配电线路故障指示器技术规范》及编制说明二○一○年三月十八日主题词:综合电网无功技术通知国家电网公司办公厅2010年3月18日印发—2—Q/GDW435—201

2、0ICS29.24029.×××备案号:×××Q/GDW国家电网公司企业标准Q/GDW435—2010农村电网无功优化补偿技术导则Technologyguideforreactivepoweroptimizationandcompensationonruralelectricpowernetwork(报批稿)2010-03-18888发布2010-03-18888实施国家电网公司发布Q/GDW435—2010目次前言·············································································

3、······················································································II1范围·····························································································································································12规范性引用文件······························

4、············································································································13术语和定义··················································································································································14无功优化补偿技术规范··············

5、················································································································25无功优化补偿建设方法······························································································································46无功优化补偿装置选型·························

6、·····································································································57无功优化补偿管理要求······························································································································5附录A(规范性资料)农网无功优化补偿典型应用模式·······················

7、···················································7编制说明··························································································································································11IQ/GDW435—2010前言本导则根据《关于下达2009年度国家电网公司规范制(修)订计划的通知》(国家电网科〔2009〕217