资源描述:
《VH301型多功能便携式振弦读数仪英文版用户手册》由会员上传分享,免费在线阅读,更多相关内容在行业资料-天天文库。
CoverHand-heldMultifunctionReaderVH301OperatingManualPOWSETWINCONNTECHWINCONNTECH
1Hand-heldMultifunctionReaderVH301WINCONNTECHOperatingManualOverviewThankyouforchoosingourVH301multifunctionreader.Thisdeviceisahand-heldreadingdevicedevelopedforvibrationwiresensor,Ithasawiderangeofsensorcompatibility,Itcanbeusedtomeasurefrequency,temperature,voltagesensor,currentsensorandstoremeasurementdata,Simultaneousmeasurementofvariousenvironmentalphysicalquantities(ambienttemperatureandhumidity,atmosphericpressure,airquality),Real-timeclock,positiondataandsensordatacorrespondonebyone,Built-inFLASHcanstoremillionsofpiecesofdata,ThecompactsizeoftheequipmentandtheuseofAAAbatteriesandotherfeaturesareconvenienttocarryandreplacebatteries。Theadditionalfunctionsofwirelesscommunicationandtimingswitchprovideconvenientconditionsforautomaticandunattendedmonitoring.OrderInformationTYPENAMEFunctionalDescriptionVH301BBasicverVibratingwiresensorreader,ManualandautomaticworkingmodesVH301FFullyfunVH301B+Environment(E)+verAnalogMeasurement(Ax)+GPS(P)+Compass(O)VH301PPlusverVH301F+UDisk(U)+wireless(Rx&G)Standardpartsofdelivery1Hand-heldreadinginstruments(VH301X)1Portablebag1ConnectorforMeasure1ConnectorforCommunication1Operationmanual(thismanual)1Softwaretools(electronicversion)DocumentversionV1.00ApplicabletofirmwareversionsV1.102TEL:+8603163093523+8601061591202
2Hand-heldMultifunctionReaderVH301WINCONNTECHOperatingManualDeviceparametersParameterConditionRangeUnitSize165x82x31(LxWxH)mm3IPgradeIP53PowersupplyAAAbatteries*4OperatingTemperature-20~80Temperature℃StorageTemperature-60~120NOGPSALK1300mAH≥8RuningHourNI-MH900mAH≥8HLi1500mAH≥10screenresolution128x128pix2EEPROM512kByteinternalmemoryFLASH8MByteexternalmemoryUdisk1~32GVibrwirefrequency100~8000HzVibrwiretemperature-60~120℃Environmental-40~125℃temperatureEnvironmentHumidity0~100%RangeAtmosphericpressure10~1200mbarAirquality-VOC0~1000ppbAirquality-CO2400~5000ppmVoltagesensor0~10VCurrentsensor0~20mATiltmeasuring±90°Vibrwirefrequency±0.2HzVibrwiretemperature±0.5℃Environmental±0.3(0~60℃)℃temperatureEnvironmentHumidity±3(25℃)%Atmosphericpressure±0.01mbarprecisionAirquality-VOC45ppbAirquality-CO250ppmVoltagesensor0.1%Currentsensor0.1%GPS(Horizontal)3mGPS(elevation)10mCompassazimuth1.5°Tiltmeasuring0.01°DocumentversionV1.00ApplicabletofirmwareversionsV1.103TEL:+8603163093523+8601061591202
3Hand-heldMultifunctionReaderVH301WINCONNTECHOperatingManualDeviceCompositionandInterfaceDefinitionUDiskExcitationVoltageScreenExcitationMethodGPSANTRunningIndicatorCapacitivebuttonsPOWSETEnvironmentalMeasuringHoleBatterysWINCONNTECHBatteryLockInterfaceFrontViewBackViewConnectorColorFunctionConnectTo9REDCoil+Coil+4BLACKCoil-Coil-①measuringline6YELLOWNTC+NTC+4BLUENTC-NTC-2YELLOWRS232-RXDComputer②communicationline3BLUERS232-TXDRS232interface5BLACKGND7485-A/VOUT+8485-B/VOUT-Note1:Themeasuringdatalinehashighvoltageoutput,anddirectcontactwithexposedpartsshouldbeavoidedduringthemeasurement.Note2:SpecialconnectorsmustbeusedtoconnecttothecomputerRS232interface。DocumentversionV1.00ApplicabletofirmwareversionsV1.104TEL:+8603163093523+8601061591202
4Hand-heldMultifunctionReaderVH301WINCONNTECHOperatingManualKeyOperationVH301hastwocapacitivetouchbuttons,[POW]and[SET],withthreeevents:click,double-click,andlongpress。Click:pressandreleasebuttonsforashortperiodoftime.Double-click:youcompletetwoclicksinashortperiodoftime.(defaultrangeof100millisecondsto1second).Longpress:pressthebuttonandholdforawhilebeforereleasing.(defaultminimumtimelengthof3seconds)Note:Thelengthofdouble-clickandlong-pressisdefinedbytheregisterparameters.Pleaserefertotheregistersdescriptionfileformoredetails.NormalmodebuttonsoperationButtonFunctionalSpecificationRemarks/ConditionsEventsNameLong[POW‹‹]Turnonandoffpress[SET››]SaveasetofdataMeasurePagesDouble-[POW‹‹]Switchtothepreviouspageclick[SET››]Switchtothenextpage[POW‹‹]SwitchthescreenbacklightClickSwitchbetweenthehome[SET››]pageandtheSettingspageNote:intheparametersettingpage,longpressthe"setting"buttontoenterthesettingmodeSetmodebuttonsoperationButtonFunctionalSpecificationRemarks/ConditionsEventsNameSwitchbetweensetmodeParametersetting[SET››]LongandnormalmodepagepressContinuouslychange[POW‹‹]parametervaluesSelectthenextparameter[SET››]Double-itemclickSelectthepreviousParametersetting[POW‹‹]parameteritemmodeChangetothenextparameter[SET››]valueClickChangetotheprevious[POW‹‹]parametervalueNote:Whensettingmode,thebacklightandpowerofffunctioncannotbeused.DocumentversionV1.00ApplicabletofirmwareversionsV1.105TEL:+8603163093523+8601061591202
5Hand-heldMultifunctionReaderVH301WINCONNTECHOperatingManualIndicatorLightDescriptionIndicatorColorStatusDescriptionoffPOWPOWredonRUNRUNgreenflashrunningIswaitingforthevibrationwiresensor①fastSENSENyellowaccess②slowMeasuringfrequencySIGSIG---FunctionsarenotyetdefinedNote①:Morethan5flashespersecondNote②:ThemeasurementflashesonceeverytimeExcitationVoltageandMethodofVibratingWireSensorMultitapswitchTapExcitationPositionExcitationmethodvoltagesource①04.5VHighvoltageexcitation,limitedvoltage120V①15.5VHighvoltageexcitation,limitedvoltage150V①26.5VHighvoltageexcitation,limitedvoltage200VFrequencyfeedbackfixedfrequencysweepmethod(High37.5V②vol)(Recommend)Frequencyfeedbackgradientfrequencysweepmethod48.5V②(Highvol)Frequencyfeedbackfixedfrequencysweepmethod(Low59.5V③vol)(Recommend)Frequencyfeedbackgradientfrequencysweepmethod610.5V③(Lowvol)711.5VPiecewisefrequencysweep1,300Hz~1500Hz812.5VPiecewisefrequencysweep2,1500Hz~2700Hz913.5VPiecewisefrequencysweep3,2700Hz~3900HzA(10)14.5VPiecewisefrequencysweep4,3900Hz~5100HzB(11)15.5VFullfrequencysweep,300Hz~5000HzC(12)16.5VUndefinedD(13)17.5VUndefinedE(14)18.5VUndefinedF(15)19.5VUndefinedNote①:Theexcitationvoltagesourceshallbegreaterthan5V.Highvolexcitationmaydamagethesensorcoil,pleaseconsultthesensormanufacturerfirst.Note②:Whenthemeasuredfrequencyvalueisnotideal,itisautomaticallyDocumentversionV1.00ApplicabletofirmwareversionsV1.106TEL:+8603163093523+8601061591202
6Hand-heldMultifunctionReaderVH301WINCONNTECHOperatingManualswitchedtohighvoltagepulseexcitation,andthehighvoltagelimitis200V.Note③:Whenthemeasuredfrequencyvalueisnotideal,itisautomaticallyswitchedtothefullfrequencysweep,andtheexcitationvoltagesourcevoltageisthesweepvoltage.BasicParametersSettingParametersettingmustbecompletedunder"parametersettingmode".Themethodsofenteringandexitingtheparametersettingmodeare:Longpressthe[SET]buttonontheparametersettingpage.Whentheparametervalueisdisplayedinreversecolor,itindicatesthatthe"parametersettingmode"hasbeenentered.EnterParameterSettingModeSwitchtotheSettingspagebydouble-clickingthe[POW]or[SET]button.Pressthe[SET]buttonforalongtimeuntilthefirstparameteronthispageisthebackcolordisplaystatus.SelecttheParametertoModifyBydouble-clickingthe[POW]or[SET]button,selecttheparametertobemodified(theparametervalueisdisplayedinreversecolor).ModifySelectedParameterValueWhenaparameterisselected,clickthe[POW]or[SET]buttontomodifythecurrentvalue.Note:Longpressthe[POW]buttoncanrealizerapidandcontinuousmodificationofparametervalue.Note:Onlyclickonthemodifiedparameterscanbesavedpermanently.ExitParameterSettingModeDocumentversionV1.00ApplicabletofirmwareversionsV1.107TEL:+8603163093523+8601061591202
7Hand-heldMultifunctionReaderVH301WINCONNTECHOperatingManualPressthe[SET]buttonforalongtimeuntilthereisnobackdisplayedparameteronthispage,indicatingthattheparametersettingmodehasbeenquit.____________SettingmodeNormalmode[MANU/AUTO]:Whetherthedeviceworksinautomatictimingmode.Whenworkinginautomaticmode,itautomaticallystartseveryhour,collectsandstoresonce,andsendseverytwohours.[GPSON/OF]:WhethertouseGPSpositioningfunction(morepowerconsumption).[DATE]:Datevalueswithinthedevice.Thedatetimevalueissavedtothedatafilewhenthedataisstored.[TIME]:Timevalueswithinthedevice.Thedatetimevalueissavedtothedatafilewhenthedataisstored.[T]:Typeofinternaltemperaturesensorofvibrationwiresensor.0:notemperaturesensor(real-timemeasurementofCPUtemperature).1~9:1k~9kthermistor.Thedefaultkvalueis3950.Pleaseconsulttechnicalsupportformodification.10:DS18B20digitaltemperaturesensor.Pleaseconsulttechnicalsupportfortheconnectionmethod.DocumentversionV1.00ApplicabletofirmwareversionsV1.108TEL:+8603163093523+8601061591202
8Hand-heldMultifunctionReaderVH301WINCONNTECHOperatingManualExportdatatocomputerStoreddatacanbeexportedtoacomputerforsavingandeditingviatheRS232interface.DownloaddatafileConnectthehandheldreadingdevicetotheRS232portofthecomputerwiththededicateddatacable;Openthefilesynchronizationtoolfilesync.exe,selectthecomputerportname,andclickthe"open"button;OpenVH301andclickthe"enterDOS"buttonofthesynchronizationtoolandclickthe"synchronize"button.Clickthe"dat"directoryontheleftofthesynchronizationtool,andalldatafilesinthisdirectoryaredisplayedontherightsideoftheinterface.Selectthenameofthefileyouwanttodownload,andclickthebuttonofdownloadicontopopupthedialogboxforsavingthefile;Clickthe"save"buttontocompletethedatafiledownload.OpendatafileYoucanusenotepadorExceltoopenthedatafiledownloadedabove.ThestepstoopenadatafileusingExcelareasfollows.OpentheExcelsoftware,click[file]-[open]onthemainmenu,andbrowsetothedirectorywherethedatafileislocated.Select"allfiles(*.*)"asthefiletype;Clickthedatafile"dat_xxx.txt"andclickthe"open"buttontopopupthedialogboxoffileimportwizard;DocumentversionV1.00ApplicabletofirmwareversionsV1.109TEL:+8603163093523+8601061591202
9Hand-heldMultifunctionReaderVH301WINCONNTECHOperatingManualSelect"separator"and"TAB"inturn,andclickthe"finish"buttontoopenthedatafile.DownloaddatafileOpendatafileDocumentversionV1.00ApplicabletofirmwareversionsV1.1010TEL:+8603163093523+8601061591202
10Hand-heldMultifunctionReaderVH301WINCONNTECHOperatingManualDatafiledescriptionAlldataarestoredintheformofchannels,withatotalof24channels,whicharedefinedasfollows:CH01:Frequencyvalueofvibratingwiresensor.Unit:0.1HzCH02:Temperaturevalueofvibratingwiresensor.Unit:0.1℃CH03:Environmenttemperature.Unit:0.1℃CH04:EnvironmentHumidity.Unit:0.1%CH05:Atmosphericpressure,unit:0.01kPCH06:AirqualityVOC,unit:PPMCH07:AirqualityCO2,unit:PPBCH08:ExtendedmeasureADC1CH09:ExtendedmeasureADC2CH10:GPSlongitude-degree.Unit:°CH11:GPSlongitude–minute.Unit:′CH12:GPSlongitude-second.Unit:0.01″CH13:GPSlatitude-degree.Unit:°CH14:GPSlatitude-minute.Unit:′CH15:GPSlatitude-second.Unit:0.01″CH16:GPSelevation.Unit:0.1MCH17:AzimuthAngle,unit:0.01degree(0degreenorth,clockwiseincrease)CH18:Tilt-x,unit:0.01degree(Theslopetotherightispositiveandthereverseisnegative)CH19:Tilt-y,unit:0.01degrees(Theforwardtiltispositiveandthereversetiltisnegative)CH20~CH20:Reserved,notusedDocumentversionV1.00ApplicabletofirmwareversionsV1.1011TEL:+8603163093523+8601061591202
11Hand-heldMultifunctionReaderVH301WINCONNTECHOperatingManualNotesUsestandardbattery:Itisrecommendedtousealkalinebatterytopowertheequipment.Theuseofotherbatterieswillcausethebatteryresidualpowerdisplayerrororfailtoturnonoroffnormally.Long-termstoragerequirements:Whennotinuseforalongtime,pleasetakeoutthebattery.Theequipmentshouldnotbeplacedinmoist,hightemperatureorlowtemperatureenvironmentforalongtime.Keepthekeysclean:Thekeyofthisequipmentiscapacitivebutton.Keepthebuttonareascleanduringusetoavoidwaterstainsorsweatstains.Usespecialinterface:Whetheritissensormeasurementorcomputerconnection,pleaseusethespecialinterfacesignallineordatalineofthisequipment.Dataexportintime:Afterstoringdata,itshouldbeexportedtothecomputerintimeandclearthestoragespace.Toomuchdatastoredinthedevicewillaffecttheoperatingefficiency.Periodiccalibrationandverification:Theequipmenthasbeencalibratedwhenitleavesthefactory,anditisrecommendedtoreturntothefactoryforre-calibrationeveryyear.Noshortconnectionline:Noshortconnectionofanytwomeasuringlinesorclamps.Correctconnection:Avoidcontactwithnon-sensorsignals.Incorrectconnectionmayleadtopermanentdamageofequipment.Avoidstaticelectricitybreakdown:Whenusedindryenvironmentsuchasautumnandwinter,specialattentionshouldbepaidnottointroducestaticelectricityintotheequipment.Donotdisassemble:Donotdisassembleorrefitequipment.DocumentversionV1.00ApplicabletofirmwareversionsV1.1012TEL:+8603163093523+8601061591202