1、电缆型号与外径尺寸对照表(埋管必须资料)序号电缆型号电缆外径(mm)备注1YJV-6KV-3*1635.90 2YJV-10KV-3*2540.50 3YJV-10KV-3*3545.40 4YJV-10KV-3*9557.10 5YJV-10KV-3*24072.90 6VV3*240+1*12055.02 7VV3*185+1*9553.30 8VV3*120+1*7044.01 9VV3*95+1*5039.52 10VV3*35+1*1627.08 11VV3*25+1*1624.91 YJV 6/6KV、6/10KV交联电缆技术参数YJV
2、 6/6KV、6/10KV交联聚乙烯绝缘聚氯乙烯护套电力电缆导体标称截面绝缘厚度护套厚度电缆近似外径电缆近似重量20℃导体电缆载流量短路电流直流电阻在空气中直埋土壤中导体屏蔽层 铜带铜丝mm2mmmmmmkg/kmΩ/kmAAKAKAKA1×253.41.8216850.7271651603.691.0833.5061×353.41.8228070.5242051905.151.0823.5011×503.41.8239770.3872452257.311.0793.4961×703.41.82512070.26830527510.21.0773.
3、4911×953.41.82714890.19337033013.81.0775.4491×1203.41.82817620.15343037517.41.0775.4491×1503.41.93020800.12449042621.71.0765.441×1853.423224530.099156048026.71.2517.591×2403.42.13431000.075466555534.61.257.5831×3003.42.23637230.060176563043.11.2567.561×4003.42.34047280.0478907
4、2557.41.2457.553导体标称截面绝缘厚度护套厚度电缆近似外径电缆近似重量20℃导体电缆载流量短路电流直流电阻在空气中直埋土壤中导体屏蔽层 铜带铜丝mm2mmmmmmkg/kmΩ/kmAAKAKAKA3×253.42.34321320.7271201253.692.958-3×353.42.34524910.5241401555.152.958-3×503.42.44830910.3871651807.312.958-3×703.42.65238840.26821022010.22.958-3×953.42.75647780.193355
5、26513.82.958-3×1203.42.85955950.15329030017.42.958-3×1503.42.96367320.12433034021.72.958-3×1853.436679540.099137538026.72.958-3×2403.43.27279290.075443543534.63.301-3×3003.43.377118550.060149548543.13.301橡皮绝缘电力电缆在空气中敷设的载流量(A)电缆型号(铜芯)500VXLVXLF、XLHF、XLQ、XLQ203*1.518193*2.524253
6、*432343*640443*1057603*1676813*251011073*351241313*501581703*701912053*952342513*1202692893*1503113373*185359388 交联聚乙烯电力电缆在空气中敷设的载流量(A)电缆型号(铜芯)6~10kV25℃30℃35℃40℃ 3*161271221661113*251661591521453*352001921841753*502432332232133*702942822702583*95351
7、3373223083*1204073913743573*1504674484294103*1855305094874653*240616591566541油浸纸绝缘麻被及铠装电力电缆在空气中敷设的载流量(A)电缆型号(铜芯)10kV25℃30℃35℃40℃ 3*16756963563*251009284753*35125115105943*501551431301173*701901701601433*952302121941733*1202652452232003*1503052822572303*
8、1853553282992683*240420338354317备注:使用铝芯电缆的时候按照80%以上电流值计算。