《嗅球容积测定对早期帕金森病的诊断价值-论文.pdf》由会员上传分享,免费在线阅读,更多相关内容在行业资料-天天文库

1、·484·JShanxiMedUniv,Jan2014.Vol45No6嗅球容积测定对早期帕金森病的诊断价值俱西驰,王伟,屈秋民,张明,吴谦,罗国刚,金晨旺,宋文峰(西安交通大学医学院第一附属医院神经内科,西安710061;陕西省人民医院预防保健科;西安交通大学医学院第一附属医院影像科;西安交通大学医学院流行病学教研室;通讯作者,E-mail:908371001@qq.tom)摘要:目的研究帕金森病(Parkinson’sdisease,PD)嗅球容积变化,探讨嗅球容积测定用于早期PD诊断的可能性。方法帕金森病病例组(PD组)及

2、对照组各18例,测定帕金森病统一评分量表(unifiedParkinson’sdiseaseratingscale,UPDRS)Ⅲ量表,进行Hoehn—Yahr分期;两组均用磁共振(magneticresonanceimaging,MRI)测定嗅球容积,并对结果进行统计学分析。结果PD组嗅球容积明显小于对照组[(90.9±15.68)mmvs(131.2±24.53)mE,P<0.001];PD组中左侧嗅球容积小于右侧嗅球容积[(41.4±10.05)mmvs(46.5±11.49)mm,P<0.01];正常对照组中两侧嗅球容积

3、无差异[(65.1±13.02)mmvs(66.3±12.94)mm,P>0.05]。结论早期帕金森病患者存在嗅球容积缩小,磁共振嗅球容积测定可帮助诊断早期PD。关键词:帕金森病;Hoehn—Yahr分期;磁共振;嗅球容积中图分类号:R741.04文献标志码:A文章编号:1007—6611(2014)06—0484—03DOI:10.13753/j.issn.1007—6611.2014.06.013DiagnosticvalueoftheolfactorybulbvolumemeasurementforParkinson’sd

4、iseaseinearlystageJUXichi,WANGWei“,QuQiumin,ZHANGMing’,wUQian,LUOGuogang,JINChenwang,SONGWenfeng(DepartmentofNeurology,FirstAfiliatedHospital,MedicalSchoolof’anflaotongUniversity,Xi’an710061,China;DepartmentofPreventionandHealthCare,People’sHospitalofShaanxiProvince;

5、DepartmentofImaging,FirstAfiliatedHospital,MedicalSchoolofXi’anJiaotongUniversity;DepartmentofEpidemiology。MedicalSchoolofXi’anJiaotongUniversity;Correspondingauthor,E—mail:908371001@qq.com)Abstract:ORctiveToinvestigatethechangesofolfactorybulbvolumeinpatientswithPar

6、kinson’sdisease(PD),andexploreitspossibilityindiagnosisofPDinearlystage.MethodsEighteenPDpatientsand18normalcontrolswerechoseninthisstudy.UP—DRSIIIscalewasusedtoevaluateHoehn-Yahrclassification.Theolfactorybulbvolumewasmeasuredbymagneticresonanceimaging(MRI),andthere

7、sultswerecomparedbetweentwogroups.ResultsOlfactorybulbvolumeinPDgroupwassignificantlylessthanthatincontrolgroup[(90.9±15.68)mmvs(131.2±24.53)mm,P<0.001].TheolfactorybulbvolumewaslessatleftsidethanthatofrightsideinPDgroup[(41.4±10.05)mmvs(46.5±11.49)mm,P<0.01].Incontr

8、olgroup,therewasnodiferenceinol—factorybulbvolumebetweentwosides[(65.1±13.02)mmvs(66.3±12.94)mm3,P>0.05].ConclusionTheolfactorybulb