1、THYSSENAUFZUGSWERKEOperatingInstructionsDiagnosticUnitIFunctions6510046TypeTypeNo.DIAGNOSTICUNITILKsensorRun:IS/RS2)UPdirectionwithISDOWNdirectionwithISProgramselectorwheelLNsensorW/W1contactorWO/WUSchützPulsesCheck-backSRmoduleSafetycircuitEKHKTKKTSeven-segment-functiondisplayflashing1)Start/Stop
2、buttonFunction0100Displayoferrorstackasper:05.00显示故障堆栈Example:ErrorExplanationWeightingBW1403AAjob-specificerrormessag任务特性故障信息Nemergencystop紧急停梯XXlanding楼层Sstopping停止YYundefined未定义Mspontaneousmessage自发信息NNexplanationsfrompage21解释见21页Bliftblocked电梯被锁定ZZNumberofmarkingflag标志编号..Boperationphase运行阶段Si
3、gnificance:Frequencylevelsoferror:含义:故障频繁度Level1infrequent1度不频繁发生Preparedby:KeinzDateof-Changes:GEGORLIssuingDept.:QMSissue:07.02RevisionD6510-046-B-E.docPage:42THYSSENAUFZUGSWERKEOperatingInstructionsDiagnosticUnitIFunctions6510046TypeTypeNo.Errorcodenumber故障代码Level10frequent10度频繁发生ErrorErrordesc
4、riptionCauses,remedyorinstructionsBW01XXInterlockcontactRKorRKDisjamminginlandingXX.门锁触点RK或RKD在XX楼层处卡住/在XX层检查门锁触点或门的机械部件。在任务特性程序中必须将门的型号编程输入CheckinterlockcontactormechanicalpartsofdoorinlandingXX.Acorrectdoortypemustbeprogrammedinthejob-specificprogram.60201Callsinhibitedviamonitoring召唤因监控作用被禁止An8
5、-kbyteRAMisrequiredinCPU.CPU中需要一块8-KBYTERAM10202QuasiZSEinlift-specificprogramreleased,butSiemensCPUstillused.在电梯特性程序中QUASI的ZSE开关被删掉,但在SIEMENS的CPU中仍使用UseThyssenCPUwithbattery-backedRAMchip(storageofpositionintheeventofpowerfailureorifHSisswitchedoff).用THYSSEN的CPU后备电池的RAM芯片(停电或HS断开时存储位置信息)10203TCMc
6、ontrolTCM控制8k-RAMnotrecognized;F800willfollow8K-RAM未识别;随之以F80010204TCMcontrolTCM控制8k-EPROMnotrecognized;F800willfollow8K-EPRAM未识别;随之以F80010280Undefinedorwrongoperationphase未定义或错误的运行阶段10301Noprovisionhasbeenmadefordisconnectlandinginlift-specificprogram.在电梯特性程序中没有编入关梯楼层Disconnectlandingnotprogramme
7、d(checkdatasheet)orincorrectordernumberonlift-specificEPROM.关梯楼层未编程(检查数据表)或电梯特性EPROM中的定单号不正确10302Noprovisionhasbeenmadeforparkinglandinginlift-specificprogram.在电梯特性程序中没有编入停泊楼层Parkinglandingnotprogrammed,etc.,same