1、后压浆施工技术规范TechnicalSpecificationofPostPressureGrouting一、设计design1、对桩径800mm桩长40m采用复式注浆法即桩端与桩侧注浆法。桩端与桩侧各对称安装二根注浆管。Doublepressuregroutingtobeadoptedfor800mmdia./40mlongpile,i.e.sideandbottomgrouting.Twogroutingpipesshallbearrangedforbottomandsiderespectively.2、注浆位置groutingposition:1)桩端注浆:注

2、浆花管应埋入终孔孔底下100-300mm,Bottomgrouting:groutingpipeshouldpenetrate100-300mmbelowthebottomofborehole.2)桩侧注浆:桩长30m/40m的桩注浆花管应设置在地面下20m/25m处的砂层中,或者15-20m/20-25m处的砂层与粘性土层界面上500mm处,具体位置由各区段工勘探孔及桩钻进时的反渣情况综合判断确定,同一建(构)筑物注浆位置宜相同(详见附图二)。Sidegrouting:groutingpipesfor30m/40mpilesshouldbeembeddedinsa

3、ndstrata20m/25munderground,or500mmabovetheintersectionof15-20m/20-25msiltysandandclaysand.Exactpositionsshallbereasonablydecidedasperout-comingsoilconditionintestboringandactualpiling.Groutingpositionforthesamestructure(building)ispreferablyidentical.(seediagram2)3、注浆管的长度:由实际施工的孔深确定,其长

4、度为实际孔深+0.6m。Lengthofgroutingpipe:shallbeasperactualboreholedepthandshouldbe0.6mlongerthanboreholedepth.4、注浆管采用DN20、δ=2.75的焊管,相邻注浆管采用丝扣连接,并用14#铁丝绑扎固定在钢筋笼的外侧。注浆管底端用丝堵封闭,距底端400mm长度范围内对称均匀钻12个φ6的注浆孔,用胶带及图钉封孔。注浆管顶部应高出砼面0.5以上,且高出地面0.2-0.3m。管顶要用丝堵封闭且用不同颜色的胶带缠绕,将桩底注浆管与桩侧注浆管区分开来。Groutingpipetyp

5、e:DN20、δ=2.75weldedpipetobeadopted,andadjacent12pipestobeconnectedwiththreadsandtightlyfixedtotheoutersideofrebarcagewith14#galvanizedwire.Bottomendofgroutingpipetobesealedwithplugand12nosofφ6groutingholestobeevenlydrilledwithinthebottom400mmofgroutingpipe,andthesameshouldbesealedwitht

6、apesandthumbnails.Topofgroutingpipeshouldbe0.5maboveconcreteleveland0.2-0.5mabovegroundlevel.Pipetopstobesealedwithplugsandwrappedwithtapesofdifferentcolorstodifferentiatebottomandsidegroutingpipes.5、注浆压力:桩侧:桩长30m为1.5MPa,桩长40m为2.0MPa;桩端:桩长30m为2.0MPa,桩长40m为2.5MPa。Groutingpressure:pilesi

7、de:1.5MPafor30mpilesand2.0Mpafor40mpiles;pilebottom:2.0MPafor30mpilesand2.5for40mpiles.6、注浆材料及注浆量:采用普通42.5级水泥,每根桩水泥用量暂定为3.0t。初始压浆时水灰比为1:1,体积为200L,余下水灰比为08:1。Groutingmaterialandquantity:normalOPC42.5gradecementtobeadoptedand30tofcementforeachpile.Initialgroutingwater-cementratioshould