1、P550更换内置RAID硬盘更换步骤维护准备:1.        备件磁盘2.        磁盘微码:3.        参考指南:PCI-XSCSIRAIDcontrollerReferenceGuideforAIX维护步骤:(约需4小时)1、做好rootvg备份(mksysb)和数据备份(强烈建议)。2、检查系统和硬件设备:用命令lsdev –Ccpdisk、errpt查询硬盘设备信息。3、用diag->Taskselection->RAIDArrayManager->PCI-XSCSIDiskArrayManager->       ListPCI-XSCS

2、IDiskArrayconfiguration检查raid信息和pdisk6   的状态。hdisk0   0B-08-ff-0,0 Degraded   RAID5Array    714.2GB pdisk6  0B-08-00-5,0 Failed     ArrayMember    142.8GB pdisk8  0B-08-01-5,0 Active     ArrayMember    142.8GB pdisk7  0B-08-00-3,0 Active     ArrayMember    142.8GB pdisk3  0B-08-01-3,0 

3、Active     ArrayMember    142.8GB pdisk5  0B-08-00-4,0 Active     ArrayMember    142.8GB pdisk4  0B-08-01-4,0 Active     ArrayMember    142.8GB 4、用以下操作再次确认硬盘槽位信息:diag->Taskselection->RAIDArrayManager->PCI-XSCSIDiskArrayManager->  DiagnosticsandRecoveryOptions>SCSIandSCSIRAIDHotPlugMana

4、ger>     IdentifyaDeviceAttachedtoaSCSIHotSwapEnclosureDevice选择对应的硬盘,按F7确认硬盘所在的槽位(磁盘的黄灯亮)5、进行磁盘更换用hotplug把硬盘更换,操作如下:Diag>TaskSelection>RAIDArrayManager>PCI-XSCSIDiskArrayManager>  DiagnosticsandRecoveryOptions>SCSIandSCSIRAIDHotPlugManager>   Replace/RemoveaDeviceAttachedtoanSCSIHotSwa

5、pEnclosureDevice把故障硬盘更换,然后按F3回到上一层菜单      SCSIandSCSIRAIDHotPlugManager>ConfigureAdded/ReplacedDevices更换硬盘后,回到diag->Taskselection->RAIDArrayManager->PCI-XSCSIDiskArrayManager->       ListPCI-XSCSIDiskArrayconfiguration可以看到pdisk6的状态是failed,比如下图:hdisk0   0B-08-ff-0,0 Degraded   RAID5Arra

6、y    714.2GB pdisk6  0B-08-00-5,0 Failed     ArrayMember    142.8GB pdisk8  0B-08-01-5,0 Active     ArrayMember    142.8GB pdisk7  0B-08-00-3,0 Active     ArrayMember    142.8GB pdisk3  0B-08-01-3,0 Active     ArrayMember    142.8GB pdisk5  0B-08-00-4,0 Active     ArrayMember    142.8G

7、B pdisk4  0B-08-01-4,0 Active     ArrayMember    142.8GB用lsdev –Ccpdisk是可以看到pdisk6是available,然后检查微码,如果磁盘微码:Version4335304B以下的就必须升级,可更换上去的磁盘微码:Version 4335304A,所以不需要升级微码。6、对RAID_5进行重建diag->Taskselection->RAIDArrayManager->PCI-XSCSIDiskArrayManager->          ReconstructaPCI-XSCSIDiskA