1、真空吸尘器翻倒测试(人体支撑式)修订日期修订单号修订内容摘要页次版次修订审核批准2011/03/30/系统文件新制定2A/0///批准:审核:编制:真空吸尘器翻倒测试(人体支撑式)1.0Purpose/目的Toevaluatethesafetyofthebodysupportedtypesamplewhentipoveredwithcontainerfilledtomaximumcapacity评估人体支撑式吸湿型样機在吸满水后在翻倒过程中是否符合UL1017安全要求2.0Definition/概念:None無.3.0ReferenceD

2、ocuments/參考文獻:U.L.1017CAN/CSA-C22.2NO.243-01,dated12-7-2001,CL5.12.6.2,5.12.6.4,5.12.6.5&5.12.6.64.0Equipment/設備:4.1LeakageCurrentTester.泄漏电流測試儀.4.2Leakagetestswitchingbox.泄漏电流测试盒4.3FrequencyConverter.变频电源4.4Stopwatch.秒表4.5WithstandingVoltageTester耐压测试仪4.6Testvessel测试容器5.

3、0GeneralInstructions/說明:5.1Testsmaybeconductedatanyambienttemperaturewithinarangeof10-40℃(50-100℉).測試可在10~40℃(50~100℉)之內的環境溫度下進行.5.2Unlessotherwisenoted,alltestsaretobeconductedwithapplianceconnectedtoa120VAC,60Hzpowersource.除非另外標注,否則所有样機都将连接在120V/60Hz電源下进行測試.5.3Allequipm

4、entusedmustbecalibratedonanannualbasis.Calibrationstickerswithlastcalibrationandcalibrationduedatemustbeaffixedtoeachinstrument..使用的所有設備都必須以一年為周期進行調校.載有最後調校日期和調校周的調校粘紙必須被粘固在每個儀表上.5.4Inthistest,recordleakagecurrentaccordingtothemethodnotedinTAREGW1004.本测试中,按照TAREGW1004所述记录

5、测试前,中,后的泄漏电流.5.5Forthistest,thesampleandvesselmustbeisolatedfromground.测试过程中,测试容器要与地绝缘.6.0Procedure/步驟:6.1Obtainarepresentativesampleoftheappliancetobetested.準備一台有代表性的樣機用於測試6.2ObtainTestResultsFormTTR1039andcompletelyfillintheinformationdescribingthesampleandtheequipmentu

6、sedpriortorunningthetest.用TTR1039測試結果的表格,在測試運作前完整地填入樣機和使用的設備的情況.6.3Connectthesample,LeakageCurrentTester&LeakagetestingswitchboxtogetherperTAREGW1004.按照TAREGW1004所述将样機,泄漏电流測試儀,泄漏电流测试盒等连接好电源.6.4Defeatthefloat.使浮子失效6.5Operatethesamplecontinuouslypickingupwateruntilthecontai

7、nerisfilledtomaximumcapacity.Thende-energized(butnotunplugged,withtheLeakagetestswitchingboxSW1open)andtipoverthesamplefor30seconds.Thetipoveristoconsistofplacingthesampletorestonitsside(approximately90degrees).Thenreturnittoitsuprightpositionandenergizeditfor30secondsdra

8、wingaironly.Thisprocedureoffillingtocapacity,tippingover,anduprightistoberepeatedforatotaloffour