1、(20__届)本科毕业设计长沙市九州宾馆空调和太阳能热水系统设计II摘要本设计长沙市九州宾馆建筑空调和太阳能热水系统设计,一层为商铺,二至四层为客房。全楼冷负荷为120.54kW,采用集中供给空调方式,制冷机组采用风冷模块机组,型号为KHAH025P,其制冷量为65kW。根据房间用途不同,通过方案比较,采用了风机盘管加新风调系统形式。风机盘管为卧式暗装,新风不承担室内负荷,室内回风与新风混合后经双层百叶风口送出。新风从墙洞或新风竖井引入,再由机房的新风机组集中处理后供应。冷冻水由屋顶的冷冻机房供给,采用了闭式同程两管制水系统。
2、水管用泡沫橡塑保温,风管采用离心玻璃棉保温。该地区的年总太阳辐照量(水平面)为4030MJ/㎡,则年平均日太阳辐照量(水平面)为11.04MJ/㎡。布局太阳能集热器总共36组,集热面积约为162m2,集热器占地面积真空管1080支。每天太阳能系统实际产热水量约为8940L。选择直流式太阳能热水循环系统。依据相关的设计手册所提供的参数,进一步完成新风机组、风机盘管、冷水机组等的选型,从而将其反应在图纸上,最终完成整个空调系统设计。关键词:风机盘管加独立新风系统;制冷机组;直流式太阳能热水循环系统。II显示对应的拉丁字符的拼音字典
3、AbstractThisdesignisaboutthegroundsourceheatpump(GSHP)forcentralairconditionerengineeringofacommercialbuildingthatlocatesinShanghai.Thereare19floorsonthegroundandafloorunderground.Mydesignispartsofthegroundfloors.Thecolddutyofthewholebuildingis997.1kW,Ichoosecentral
4、airconditioningforthisbuilding,therefrigeratingmachineisgroundsourceheatpumpwhichmodelisJNSRS-1230,andthecoolingcapacityare1148kW.Accordingtodifferentfunctionsoftherooms,PAU+FCUsystemandcompleteairsystemareadoptedbywayoftechnicalandeconomicanalysis.Thefreshairdoesn’
5、tundertakeindoorloadanddeliversairthroughdoubledeflectiongrilleaftermixingthereturnairinthehorizontalrecessedfancoil.Thereturnairisharnessedonetimebytheairhandlingunitinthecompleteairsystemandthehandledairisdeliveredthroughairdiffuserbyceilingairsupply.Thefreshairis
6、suppliedbyholeorshaftandhandledbythefreshairhandlingunit.Thechilledwaterwhichisaclosedtwo-pipedirectreturnwatersystemissuppliedbytherefrigeratingplantroom.Thethermalinsulationmaterialofwaterpipeandairductarefoamplasticsandcentrifugalglasswoolrespectively.Thesystemin
7、thestaircaseandthefloorsabovefifthcanexhaustairbyitself.Thepreventingandexhaustingsmokesystemisusedforthefirstandsecondflooranditadoptsthesamewaytoexhaustairandsmoke.Measuresofnoiseeliminationanddampisconsideredduringthedesign.Basedontherelevantmanualsprovidedbyair-
8、conditioningdesignparameters,andthencompletetheselectionofthefreshairunits,pumpsandwaterchillingunits,whichwillbereflectedintheirdrawings,