1、ChipMonolithicCeramicCapacitor贴片独石陶瓷电容器Testing/MeasuringCondition测试/测定条件Note:注:Theinformationofthismaterialareasofthedatementionedabove.Theyaresubjecttochangewithoutadvancenotice.Ifthereareanyquestions,pleasecontactoursalesrepresentativesorproductengi

2、neers.对于这些材料信息以上面的日期为准。信息若有变更,恕不另行通知。若有任何疑问,请与我公司销售代表或产品工程师联系。ContentsContents内容1.MeasuringEquipment&Fixture测量设备和治具2.CalibrationofMeasuringEquipment校正测量设备3.Q/D.F.Specification&TestCondition(MLCC)Q/D.F.的规格和测试条件(MLCC)4.MeasuringProcedure测量程序5.Additional

3、Information附加信息1.1.MeasuringEquipmentMeasuringEquipment测量设备Generally,weusethe“LCRMeter”asinstrumentformeasuring‘CapacitanceValue’and‘D.F.’.TypicalLCRMetersis“4284A”and“4286A”ofAgilentTechnologies.WecanproceedtestingincludingHI-CAP.(1uF≦CapacitanceValu

4、e)一般来说,我们都运用“LCR测定计”作为测量电容量和“D.F.”的工具.典型的LCR测定计是Agilent的“4284A”和“4286A”。我们可以测试高容量的电容器。(1uF≦容量)4284A4268APhoto1.Pictureofmeasurementinstrument图片1.测量工具的图片1.1.MeasuringEquipment(Fixture)MeasuringEquipment(Fixture)测量设备(固定设备)Themeasurementtestfixtureshould

5、choosetheonesuitablefortheLCRmeter.Thetypicaltestfixtureusedforthechiptypeisasfollowings.Therearetwotypemeasurementtestfixture.Theonelike16034E,weputachipatcertainspotofthetestfixture,andchipismeasuredbyputtingapintoedgesideofachip.Theotherlike16334E,

6、theshapeistweezers,wegripbothendsofachipandmeasure.测试治具应该选择一个合适于LCR测定计的测试治具。典型的适应于贴片类型测试治具如下所示。有两种测量测试治具。其中一个如16034E,将一个贴片放测试治具的测试点,然后贴片就会被一个顶针的一边所测量。另外如16334E,形状是镊子,紧夹着一个贴片的两端进行测试。16034E16334APhoto2.Pictureofmeasurementtestfixture图片2.测量测试的固定设备的图片2.2.

7、CalibrationofMeasuringEquipmentCalibrationofMeasuringEquipment测量设备的校正Calibrationisoneoftheimportantfactorforaccuratemeasuring.校正是精确测量的一个重要因素CalibrationisdonewithCOMPENofMEASSETUP.校正在MEASSETUP下的COMPENShort短路CalibrationdoesShortfirst.Pleaserefertothefol

8、lowingphotographfortheShortcondition.Atthistime,pleaseconfirmRsisbelow0.03Ω.Pleasewashtheterminalwiththeacetoneetc.whennotbecomingbelow0.03Ω.校正先做短路。请参考以下短路条件的图片。在这个时候,请确认Rs是小于0.03Ω。请用丙酮等冲洗终端,如果校正结果大于0.03Ω。16034E16334APhoto3.Calibration-Shortco