欢迎来到天天文库
浏览记录
ID:39675250
大小:890.98 KB
页数:27页
时间:2019-07-09
《安全稳定自动控制装置专用技术规范》由会员上传分享,免费在线阅读,更多相关内容在行业资料-天天文库。
1、110kV低频低压减载装置和过负荷联切装置通用技术规范压(2009年版)国家电网公司物资采购标准安全稳定自动控制装置卷110kV低频低压减载装置和过负荷联切装置通用技术规范(编号:1103001-0110-00)国家电网公司发布中国电力出版社1国家电网公司物资采购标准(2009年版)安全稳定自动控制装置卷减载装置册本规范对应的专用技术规范目录序号名称编号1110kV低频低压减载装置专用技术规范11030010110012110kV过负荷联切装置专用技术规范11030010110022110kV低频低压减载装置和过负荷联切装置通用技术规范110k
2、V低频低压减载装置和过负荷联切装置采购标准技术规范使用说明1.本物资采购标准技术规范分为标准技术规范通用部分和标准技术规范专用部分。2.项目单位根据需求选择所需设备的技术规范。技术规范通用部分条款、专用部分标准技术参数表和使用条件表固化的参数原则上不能更改。3.项目单位应按实际要求填写“项目需求部分”。如确实需要改动以下部分,项目单位应填写专用部分“项目单位技术差异表”,并加盖该网、省公司物资部(招投标管理中心)公章,与辅助说明文件随招标计划一起提交至招标文件审查会:1)改动通用部分条款及专用部分固化的参数;2)项目单位要求值超出标准技术参数值范围;3
3、)根据实际使用条件,需要变更环境温度、湿度、海拔高度和耐受地震能力等要求。经招标文件审查会同意后,对专用部分的修改形成“项目单位技术差异表”,放入专用部分表格中,随招标文件同时发出并视为有效,否则将视为无差异。4.投标人逐项响应技术规范专用部分中“1标准技术参数表”、“2项目需求部分”和“3投标人响应部分”三部分相应内容。填写投标人响应部分,应严格按招标文件技术规范专用部分的“招标人要求值”一栏填写相应的投标人响应部分的表格。投标人还应对项目需求部分的“项目单位技术差异表”中给出的参数进行响应。“项目单位技术差异表”与“标准技术参数表”和“使用条件表”
4、中参数不同时,以差异表给出的参数为准。投标人填写技术参数和性能要求响应表时,如有偏差除填写“投标人技术偏差表”外,必要时应提供证明参数优于招标人要求的相关试验报告。5.对扩建工程,如有需要,项目单位应在专用部分提出与原工程相适应的一次、二次及土建的接口要求。6.技术规范范本的页面、标题等均为统一格式,不得随意更改。7.一次设备的型式、电气主接线和一次系统情况对二次设备的配置和功能要求影响较大,应在专用部分中详细说明。3国家电网公司物资采购标准(2009年版)安全稳定自动控制装置卷减载装置册目次110kV低频低压减载装置和过负荷联切装置采购标准技术规范使
5、用说明····················································31总则·································································································································································51.1引言·····················································
6、·······································································································51.2供方职责·····················································································································································52技术规范要求···········
7、······································································································································52.1使用环境条件·······································································································································
8、········52.2保护装置额定参数···························
此文档下载收益归作者所有