欢迎来到天天文库
浏览记录
ID:39625822
大小:340.00 KB
页数:6页
时间:2019-07-07
《跨距计算原理》由会员上传分享,免费在线阅读,更多相关内容在教育资源-天天文库。
1、2.按强度条件计算允许跨距一般工业管道按强度条件计算允许跨距,如表2-2所示,表2-2按强度条件计算允许跨度序号项目内容1计算原则管道自重弯曲应力不应超过管材的许用外载弯曲应力值,以保证管道的安全,根据这原则确定管道允许跨距,称为按强度条件计算的管道允许跨距2计算方法对于连续敷设、均布荷载的水平直管,如图2-1所示,管道(或管架)的最大允许跨距,可按下列公式计算,即(2.1)式中,——管道或管架最大允许跨度m,——管道单位长度计算荷载(N/m),=管材重+保温重+附加重,如表2-4、表2-5所示。——管道截面抗弯截面系数(cm3,)如表15-15(726/709)所示,——管道横向焊缝
2、系数,如表2-6所示——钢管热态许用应力(N/mm2),如图15-8(717/700)所示。3.按刚度条件计算允许跨距一般工业管道按刚度条件计算允许跨距,如表2-3所示,表2-3按刚度条件计算允许跨度序号项目内容1计算原则管道在一定跨度下总有一定的挠度,由管道自重产生的弯曲挠度不应超过管道跨距的0.005(当疏水、放水坡度=0.002时)。根据对挠度的限制所确定的管道允许跨距叫做按刚度条件计算的管道允许跨距。2计算方法对于连续敷设、均布荷载的水平直管,如图2-1所示,管道(或管架)的最大允许跨距,可按下列公式计算,即(2.2)式中,——管道或管架最大允许跨度m,——管道单位长度计算荷载
3、(N/m),=管材重+保温重+附加重,如表2-4、表2-5所示。——在计算温度下钢材弹性模量(N/mm2),如表4-20所示,——管道截面惯性距,如表15-15所示——管道放水坡度,。表2-4不保温管道单位长度计算荷载序号公称通径/mm外壁壁厚/mm管道重/(kg/m)凝结水重/(kg/m)管内充满水重/(kg/m)不保温管单位计算荷载气管体/(N/m)液管体/(N/m)11518222.30.7891.410.0400.040.200.208.1314.229.7015.79220252.52831.391.850.0620.0660.310.3314.2418.8316.6721.
4、38325323323.52.152.460.110.100.530.4922.1625.1026.2828.93432383383.52.592.980.160.150.800.7626.9730.6933.2536.67540453453.53.113.580.240.2241.201.1332.8537.3142.2746.19650573.55744.625.190.390.381.961.8849.1354.6364.5369.34765733.57346.006.810.680.663.423.3265.5173.2592.3899.338808948.381.035.15
5、92.28132.689100108410.261.187.85112.19177.6010125133412.731.8412.27142.88245.17111501594.517.152.6517.67194.17341.4612200219631.525.0533.65358.62639.0913250273745.927.9052.69527.79967.0314300325862.5411.2574.99723.621348.691535037773778377963.8772.8081.6815.5215.3515.15103.5102.1101.0778.54864.4
6、5949.571641.321718.111791.461640042674268426972.3382.4792.5520.019.8019.61133.3132.0130.70905.441002.921099.912016.522103.212189.321745048774788478981.3192.73104.1025.1025.2025.0208.30206.70205.101190.121312.201433.522926.373035.213143.191850050075008500990.11102.81115.1231.2531.0030.76208.30206
7、.70205.101190.121312.201433.522926.373035.213143.191960063096301063011137.81152.89167.9144.1043.8043.52294.0292.0290.01783.911928.852073.404234.574362.844490.52注:表中,不保温管计算荷载为气管体=(管材重+凝结水重)9.81液管体=(管材重+管内充满水重)9.81表2-5保温管道保温结构
此文档下载收益归作者所有