欢迎来到天天文库
浏览记录
ID:32368321
大小:293.57 KB
页数:5页
时间:2019-02-03
《国网北京市电力公司》由会员上传分享,免费在线阅读,更多相关内容在工程资料-天天文库。
1、国网北京市电力公司昌海500kV线路升高改造工程环境影响报告书(简本)环评单位:中国电子工程设计院【环境影响评价资质证书:国环评证甲字第1050号】2018年11月目录1.工程概况·······················································12.工程建设必要性················································13.环境保护目标··················································14.
2、环境质量现状··················································25.施工期环境影响分析···········································36.营运期环境影响分析···········································37.环境保护措施··················································38.选线合理性分析······························
3、··················49.结论···························································4I1.项目概况项目名称:昌海500kV线路升高改造工程建设单位:国网北京市电力公司建设地点:北京市昌平区建设内容及规模:拆除现状昌海54#、53#直线塔,在现状昌海54#直线塔东侧新立一基直线、53#塔东侧新建一基耐张塔,新立铁塔两侧与现状线路相接。本段改造起点为现状昌海52#,终点为现状昌海55#。2.建设必要性由于新建聂各庄~四家庄线路在钻越现状昌海500k
4、V单回线路时交叉跨越距离无法满足设计规范中相关安全距离的要求,因此需要对现状昌海线路进行加高改造。3.环境保护目标根据现场调查结果,本项目评价范围内没有自然保护区、风景名胜区、世界文化和自然遗产地、文物保护单位、具有特殊历史、文化、科学、民族意义的保护地、居民区、学校、医院、办公楼等,变电站站址及输电线路评价范围无环境保护目标。4.环境质量现状4.1地表水环境质量现状1本项目所在区域主要地表水体为京密引水渠。京密引水渠属北运河水系,水体功能为集中式饮用水水源一级保护区,水质分类为II类。根据北京市环保局网站2018年9月河流
5、水质状况公告,京密引水渠现状水质类别为II类。4.2声环境质量现状根据2016年12月1日对输电线路沿线的声环境现状监测结果可知,声环境现状监测值满足《声环境质量标准》(GB3096-2008)中相关标准限值要求。4.3电磁环境现状根据2016年12月1日对输电线路沿线处电磁环境现状监测可知,输电线路沿线处工频电场强度现状值、工频磁感应强度现状值均满足《电磁环境控制限值》(GB8702-2014)中电场强度4000V/m、磁感应强度100µT的公众曝露控制限值的要求。5.施工期环境影响分析本项目施工期应加强对施工现场的管理,
6、严格执行《北京市建设工程施工现场管理办法》[北京市人民政府令(第247号)],在采取有效的防护措施后,可最大限度地降低施工期间对周围环境的影响。6.营运期环境影响分析6.1声环境影响分析2架空线路运营期间对沿线环境会产生一定强度的可听噪声。6.2电磁环境影响分析根据对本项目500kV架空线路的工频电磁场强度预测及类比结果可知,本项目产生的工频电场强度满足4000V/m评价标准限值的要求,工频磁感应强度满足0.1mT标准限值的要求。7.环境保护措施7.1声环境保护措施通过选择合理的施工时间,及采取隔声、消声等降噪措施后,产生的
7、噪声满足标准限值的要求。7.2电磁环境保护措施输电线路沿线为道路,通过合理布局、优化导线布置等方式,本项目产生的电磁环境影响均满足相应评价标准限值要求。8.选址选线合理性分析本项目选址选线经建设单位、设计单位及相关部门现场勘察确定,符合城镇规划和电网规划。9.结论昌海500kV线路升高改造工程在落实本报告环保措施后,污染物达标排放,对环境的影响在可接受的范围内。从环保角度分析,昌海500kV线路升高改造工程的建设是可行的。3
此文档下载收益归作者所有