《潮流与POWERWORLD 校对.doc》由会员上传分享,免费在线阅读,更多相关内容在学术论文-天天文库

1、选择接线方案3,4进行设计工作用经济电流密度法,确定线路的截面和型号:接线方案3:注:在用powerworld软件进行潮流计算时,用单回路搭建模型再将所有线路阻抗值除以2。以线路初始参数均选用LGJ70,再根据得到的潮流,由公式:计算出其导线截面积,并根据所得导线截面积选取新的导线型号,再进行下一次迭代计算,直到导线型号不需要更改为止:J=1.15A/mm2UN=110kv线路L/km迭代(1)导线型号、参数MWMvarMVAS=I/J更改导线型号1-220LGJ-708.368.0411.652LGJ-701-624LGJ-702.4113.81463LGJ-702-332LGJ-7

2、01.964.454.922LGJ-703-640LGJ-704.240.654.321LGJ-704-719LGJ-7013.651.8413.862LGJ-704-525LGJ-703.513.164.722LGJ-705-626LGJ-7011.49.2514.763LGJ-705-721LGJ-7016.751.9616.977LGJ-95由上表进行第二次迭代:线路L/km迭代(1)导线型号、参数MWMvarMVAS=I/J更改导线型号1-220LGJ-708027.511.251LGJ-701-624LGJ-702.3112.112.356LGJ-702-332LGJ-701

3、.94.04.520LGJ-703-640LGJ-704.30.24.319LGJ-704-719LGJ-7012.851.9413.863LGJ-704-525LGJ-702.613.14.118LGJ-705-626LGJ-705.73.66.831LGJ-705-721LGJ-9517.70.117.780LGJ-95此时所有导线型号已近不需要更改,迭代结束。方案三线路的截面和型号如上表。方案3matlab潮流计算与powerworld仿真潮流计算的对比(1)方案三仿真电路图如下仿真结果如下两个个图所示:(2)用matlab程序得到的潮流计算取基准值为SB=100MW,VB=11

4、0kVB1矩阵:1、支路首端号;2、末端号;3、支路阻抗;4、支路对地电纳5、支路的变比;由各条线路参数的实名值和基准值计算线路参数标幺值,以及上述B1矩阵的要求得出如下的矩阵B1B1=[1,2,0.07438+0.0714i,0,1;1,6,0.089256+0.08568i,0,1;2,3,0.119+0.114248i,0,1;3,6,0.14876+0.1428i,0,1;4,5,0.09297+0.089256i,0,1;4,7,0.07066+0.0678i,0,1;5,6,0.09669+0.0928i,0,1;5,7,0.05727+0.072198i,0,1;]B2=

5、[0.306+0.054j,0.032+0.02j,1,1,1;0,0.063+0.035j,1,1,2;0,0.062+0.038j,1,1,2;0,0.102+0.05j,1,1,2;0,0.085+0.038j,1,1,2;0,0.094+0.05j,1,1,2;0.085+0.015j,0,1,1,3;]运行结果:matlab程序运行结果与powerworld仿真结果的对比节点/支路项目1/1-22/1-63/2-34/3-65/4-56/4-77/5-65-7电压标幺值Powerworld仿真结果1.00000.988360.981370.989540.989910.9875

6、91.00001Matlab运行结果1.0000.98790.980380.98900.98870.98591.0000Powerworld仿真结果0.0013+0.0013i0.0039+0.0037i0.0005+0.0005i0.0003+0.0003i0.0002+0.0002i0.0009+0.0009i0.0008+0.0008i0.0018+0.0017i支路功率损耗Matlab0.0013+0.0038+0.0005+0.00026+0.00021+0.00089+0.003+0.00123+运行结果0.0013i0.0036i0.0005i0.00025i0.0002

7、i0.00086i0.0029i0.00155i数据基本相近。接线方案4:以线路初始参数均选用LGJ70,再根据得到的潮流,由公式:计算出其导线截面积,并根据所得导线截面积选取新的导线型号,再进行下一次迭代计算,直到导线型号不需要更改为止:J=1.15A/mm2UN=110kv线路L/km迭代(1)导线型号、参数MWMvarMVAS=I/J更改导线型号1-220LGJ-7014.30.214.365LGJ-701-624LGJ-7018.34.