1、完美WORD格式编辑血库标准操作规程(SOP)检验科2015-01修订目录第一章血库仪器标准操作规程第一节Dianafuge标准操作规程···········································3第二节80-2离心机标准操作规程·········································3第三节CU600型电热恒温水箱标准操作程序································4第四节SANYOMBR-107D(H)贮血冰箱标准操作程序············

2、··········4第五节Haier低温冰箱标准操作程序······································4第六节海尔冰箱标准操作程序··········································5第七节医院血库管理软件应用标准操作规程································5第八节SJW系列数码恒温血小板振荡保存箱标准操作规程·····················6第九节WGH-I型数码恒温解冻箱标准操······················

3、·············6学习指导参考资料完美WORD格式编辑第二章血库项目标准操作规程第一节血样采集和送检、血型复查及血源组织标准操作程序····················7第二节ABO&Rh(D)血型复检标准操作规程·······························8第三节Rh血型鉴定标准操作程序········································9第四节红细胞血型抗体筛查标准操作规程·································11第五节抗人球蛋白试验

4、··············································14第六节血液交叉配血试验标准操作规程··································15第七节血液出库(发血)标准操作规程···································17第八节数据记录及费用收取标准操作规程·································17第九节血液申领、入库、核对、贮存标准操作规程···························19第十节血液报

5、废(失效)标准操作规程····································19第十一节输血反应处理标准操作规程······································20第十二节实验室消毒和污物处理标准操作规程·······························21第十三节血库交接班标准操作规程·······································21第十四节血液质量管理标准操作规程···································

6、···22第十五节血库夜班操作规范·············································23第十六节应急预案操作规程·············学习指导参考资料完美WORD格式编辑································24第十七节贮存式自身输血(PABD)标准操作规程····························26第十八节临床医师用血申请操作规程······································28第十九节临床护士输血操作规程·

7、········································28血库标准操作规程第一章血库仪器标准操作规程第一节Dianafuge标准操作规程一、Dianafuge标准操作规程(一)Dianafuge开/关机程序1.开机把仪器电源开关拨到“Ⅰ”(开)的位置,开始正确运行。2.关机把仪器电源开关拨到“0”(关)的位置。(二)Dianafuge标准操作程序1.Dianafuge离心机应放置于水平台桌上,电源(压)须匹配。2.离心机在离心前,先按OPEN,此时门盖打开,放入检测卡(需对称放置),放入完毕后,用手

8、把门盖按下,然后按START,离心机开始转动,10分钟后自动报警开门盖,取出卡片,最后把门盖按下关好。二、Diana-Incubator标准操作规程(一)Diana-Incubator开/关机程序1.开机①按顺序依次打开电源开关。②把仪器电源开关拨到“Ⅰ”(开)的位置,开始正确运行。2.关