资源描述:
《安川(yaskawa)gpd系列变频器英文说明书》由会员上传分享,免费在线阅读,更多相关内容在教育资源-天天文库。
1、MagneTekGPD505TechnicalManualGPD505SIMPLIFIEDSTART-UPPROCEDUREThisprocedurewillquicklygetyouupandrunningusingtheDigitalOperatorkeypadorausersuppliedremoteoperatorcontrol.ItassumesthattheGPD505andmotorarecorrectlywired(seepages1-12thru1-15),andstart-upistobeperformedwithoutanychan
2、gestofactorysetparameters.Detailedinformationonthemanyotherfeaturesofthisdrivewillbefoundinlatersectionsofthismanual.INSTALLATION1.Becertainyourinputvoltagesource,motor,anddrivenameplatesareallmarkedeither230Vor460V.Othervoltagescanbeused,butrequireadditionalprogramming;seeSectio
3、n5.2.Mountdriveonaverticalsurfacewithadequatespaceforaircirculation.3.RemovefrontcoverwithDigitalOperator,fitconduittobottomplate,andconnectpowerandgroundwiresasshown.CAUTIONBecertainyouconnectinputpowertoterminalsL1,L2,andL3only,orseriousdamagewillresult.ConnectmotortoterminalsT
4、1,T2,andT3only.KEYPADOPERATION1.ReplacefrontcoverandDigitalOperatorandapplyinputpower-Keypaddisplayshows"0.0";REMOTESEQ&REFLEDSandSTOP/RESETLEDareon,andFrefFunctionLEDislit.2.SelectLOCALModebypressingLOCAL/REMOTEkey-REMOTESEQ&REFLEDswillgoout.3.EnterFrequencyReference-Pressingthe
5、“uparrow”keywillincreasedisplayedfrequencyvalue;pressingthe“downarrow”willdecreasethedisplayedvalue.Increasethefrequencyreferencedisplayto"6.0"(Hz).PresstheENTERkeytostoreorwritethisvaluetothedrive.4.ViewtheDriveOutputFrequency-PresstheDSPLkeyonce.TheFrefFunctionLEDwillgoout,andt
6、heFoutFunctionLEDwillturnon.5.RunForward-PresstheRUNkey.Themotorshouldrunat10%(6/60)ofitsbasespeed;theRUNLEDwillturnon,andtheSTOP/RESETLEDwillgoout.NOTE:Ifthedirectionofmotorrotationisincorrect,presstheSTOP/RESETkey.Whenmotorhasstopped,removepower,waitforthe“CHARGE”lighttogoout,r
7、emovethedrivecoverandswitchthemotorleadsatterminalsT1&T2.Replacedrivecoverandre-applyinputpower.6.ChangeFrequency-PresstheDSPLkeyrepeatedlyuntiltheFrefFunctionLEDturnson.Anewfrequencyreferencecanbesetbyusingthe“uparrow”and“downarrow”keysasinstep3.Notethatthedriverespondstoeachnew
8、valueonlyaftertheENTERkeyispressed(unles