1、TestprotocolChilledWaterGenerationYork(WuXi)AirConditioningandRefrigerationCo.,Ltd.bHAcGMP-YK-SAT-001SectionOne:RunningProcedure开机程序开机调试工作内容CONTENTOFRUNNING一.检查调整InspectingandadjustingA.机组外围检查(下列项目若符合要求,请在“是”前的£中打“ü”;若不符合要求,请在“否”前的£中打“ü”,并在虚线上说明)Inspectingtheperipheryoftheunit(Ifth

2、efollowingitemsmeettherequirements,pleasedraw“ü”in£atthefrontof“Yes”;ifnot,pleasedraw“ü”in£atthefrontof“No”,andillustratingthereasonatthebrokenline)安装水平是否符合规范:£是(Yes)£否(No)Iftheinstallationlevelmeetsthespecificationsornot:水流开关安装位置是否符合规范:£是(Yes)£否(No)Iftheinstallationlocationofthefl

3、owswitchmeetsthespecificationsornot冷冻水系统清洗是否符合规范:£是(Yes)£否(No)Iftheflushingofthechilledwatersystemmeetsthespecificationsornot冷冻水系统放气是否符合规范:£是(Yes)£否(No)Iftheair-exhaustingofthechilledwatersystemmeetsthespecificationsornot冷冻水泵检查是否符合规范:£是(Yes)£否(No)Iftheinspectionofthechilledwaterpum

4、pmeetsthespecificationsornot冷却水系统清洗是否符合规范:£是(Yes)£否(No)Iftheflushingofthecoolingwatersystemmeetsthespecificationsornot冷却水系统放气是否符合规范:£是(Yes)£否(No)Iftheair-exhaustingofthecoolingwatersystemmeetsthespecificationsornot是否具备冷负荷:£是(Yes)£否(No)Ifpossessingtherefrigerationdutyornot是否准备好控制电源:

5、£是(Yes)£否(No)Ifmakinggoodreadyofthecontrollingpower5/52021-6-11TestprotocolChilledWaterGenerationYork(WuXi)AirConditioningandRefrigerationCo.,Ltd.bHAcGMP-YK-SAT-001控制电压:伏特(Volt)Controllingvoltage是否准备好各项电源:£是(Yes)£否(No)Ifmakinggoodreadyofallitemsofpowersupply是否安装好水流开关:£是(Yes)£否(No)I

6、fwell-installingtheflowswitchornot是否安装好与水泵联锁:£是(Yes)£否(No)IftheinterlockwithwaterpumpinstallationwellornotA.机组阀门检查Theinspectionoftheunitvalves£已检查和开启应开启的阀门:Haveinspectedandturnedonallthevalveswhichshouldbeturnedon故障阀门及处理:FailurevalvescheckandtheirdisposalB.电机绝缘检查Motorinsulationinsp

7、ecting用伏绝缘表测量电机绝缘:UseVInsulationtesterstomeasurethemotorinsulationA相-地Phase-earth兆欧MΩ,standardis>20MΩB相-地Phase-earth兆欧MΩ,standardis>20MΩC相-地Phase-earth兆欧MΩ,standardis>20MΩ   A-B相Phase兆欧MΩ,standardis>20MΩA-C相phase兆欧MΩ,standardis>20MΩB-C相phase兆欧MΩ,standardis>20MΩC.联轴器检查(已检查的请在£中打“ü”,

8、需要时请在虚线上详细说明)Thecouplingin